Important note about upgrading your software
Customers with inForm software version 2.0 or earlier will need to upgrade their software license to update to version 3.0. Please contact us for your upgrade options.
How to install the inForm software
If this is the first time installing the inForm software, you need to install the R-installation package by following these instructions:
- Download the “R installation package” file.
- Unzip the file.
- Double click on the “install_R_and_packages.bat” file to install the software.
- Follow the prompts.
Once the R-installation package is installed on the computer, you can download and install the inForm software version 3.1.0.
Download the inForm software
Below is the latest version of the software as well as documents that will assist you with using the inForm software.
inForm software version 3.1.0
inForm user guide
inForm release notes
Software compatibility information
Some files are read by multiple Akoya acquisition and analysis software programs to facilitate unmixing and analysis workflows. Due to major updates in the combined release of the PhenoImager HT 2.1.0, Phenochart 2.2.0, and inForm 3.0.0 software, outputs from these versions are not backward compatible with previous versions of software. However, files from previous versions of software are forward compatible. These compatibility considerations are detailed in the chart below.
| Source outputs | Vectra Polaris 1.x.x | Phenolmager HT 2.x.x | Phenochart 1.x.x | Phenochart 2.x.x | inForm 2.x.x | inForm 3.x.x |
|---|---|---|---|---|---|---|
|
Scanning protocols from Vectra Polaris 1.x.x |
Yes |
Yes |
N/A |
N/A |
N/A |
N/A |
|
Scanning protocols from Phenolmager HT 2.x.x |
No |
Yes |
N/A |
N/A |
N/A |
N/A |
|
QPTIFF images from Vectra Polaris 1.x.x |
N/A |
N/A |
Yes |
Yes |
Yes |
Yes |
|
QPTIFF images from PhenoImager 2.x.x |
N/A |
N/A |
Some* |
Yes |
No |
Yes |
|
IM3 images from Vectra Polaris 1.x.x |
N/A |
N/A |
N/A |
N/A |
Yes |
Yes |
|
IM3 images from Phenolmager HT 2.x.x |
N/A |
N/A |
N/A |
N/A |
Yes |
Yes |
|
Annotations from Phenochart 1.x.x |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
|
Annotations from Phenochart 2.x.x |
No |
Yes |
No |
Yes |
No |
Yes |
|
Algorithms from inForm 2.x.x |
N/A |
N/A |
N/A |
N/A |
Yes |
Yes |
|
Algorithms from inForm 3.x.x |
N/A |
N/A |
N/A |
N/A |
Yes |
Yes |
|
Projects from inForm 2.x.x |
N/A |
N/A |
N/A |
N/A |
Yes |
Yes† |
|
Projects from inForm 3.x.x |
N/A |
N/A |
N/A |
N/A |
No |
Yes |
|
Spectra extracted from inForm 2.x.x can be exported as an unmixing library for HT 2.x.x |
N/A |
N/A |
N/A |
N/A |
No |
Yes |
|
Spectra extracted from inForm 3.x.x can be exported as an unmixing library for HT 2.x.x |
N/A |
N/A |
N/A |
N/A |
No |
Yes |
*Standard 8-bit QPTIFFs can be operated for viewing, but not all annotation features are available. Extended Range or Unmixed QPTIFFS cannot be opened.
†Two considerations: 1) Due to the slight changes to the assignment of cell IDs, phenotyping training sets from inForm 2.x.x cannot be used for re-training phenotyping classifiers in inForm 3.x.x. In this case, inForm 3.x.x will post a message that you can run the algorithm’s phenotype step with its current training or use inForm 2.8 or earlier to add training cells or revise phenotyping. 2) For projects created in inForm 2.8 with imagery that has 10+ channels, phenotyping computation may become unusably slow in inForm 3.x.x. It is recommended that inForm 2.8 projects with imagery that has 10+ channels are only run in inForm 2.8. New projects created in inForm 3.0 do not have this issue.