NF-LIGHT®: Ultra-Sensitive NFL Assay for Neurology Research
NF-LIGHT®, our Nfl assay, is an immunoassay kit for the ultra-sensitive measurement of neurofilament light levels in serum, plasma and…
Posted on
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY | SEPTEMBER 25, 2020
Rosén A, Gennser M, Oscarsson N, Kvarnström A, Sandström G, Blennow K, Seeman-Lodding H and Zetterberg H.
Eur J Appl Physiol (2020).
DOI: https://doi.org/10.1007/s00421-020-04499-y
ABSTRACT
Purpose
A prospective and controlled observational study was performed to determine if the central nervous system injury markers glial fibrillary acidic protein (GFAp), neurofilament light (NfL) and tau concentrations changed in response to a saturation dive.
Methods
The intervention group consisted of 14 submariners compressed to 401 kPa in a dry hyperbaric chamber. They remained pressurized for 36 h and were then decompressed over 70 h. A control group of 12 individuals was used. Blood samples were obtained from both groups before, during and after hyperbaric exposure, and from the intervention group after a further 25–26 h.
Results
There were no statistically significant changes in the concentrations of GFAp, NfL and tau in the intervention group. During hyperbaric exposure, GFAp decreased in the control group (mean/median − 15.1/ − 8.9 pg·mL−1, p < 0.01) and there was a significant difference in absolute change of GFAp and NfL between the groups (17.7 pg·mL−1, p = 0.02 and 2.34 pg·mL−1, p = 0.02, respectively). Albumin decreased in the control group (mean/median − 2.74 g/L/ − 0.95 g/L, p = 0.02), but there was no statistically significant difference in albumin levels between the groups. In the intervention group, haematocrit and mean haemoglobin values were slightly increased after hyperbaric exposure (mean/median 2.3%/1.5%, p = 0.02 and 4.9 g/L, p = 0.06, respectively).
Conclusion
Hyperbaric exposure to 401 kPa for 36 h was not associated with significant increases in GFAp, NfL or tau concentrations. Albumin levels, changes in hydration or diurnal variation were unlikely to have confounded the results. Saturation exposure to 401 kPa seems to be a procedure not harmful to the central nervous system.
Neurology
Poster Background Developing effective therapies for glioblastoma (GBM) relies on robust preclinical animal models that enable detailed investigation of tumor biology, discovery of therapeutic targets, and evaluation of new treatment…
Oncology
Poster Background Ultrahigh-Plex Single-cell Spatial Phenotyping has revealed valuable insights into the tumor immune microenvironment (TiME) for biomarker discovery and stratification of clinical responses. Metabolic reprogramming is a key hallmark…
Neurology
Alzheimer’s Research and Therapy | August 26, 2024 Sampani K, Ness S, Tuz-Zahra F, Aytan N, Spurlock EE, Alluri S, Chen X, Siegel NH, Alosco ML, Xia W, Tripodis Y,…
Neurology
Poster The intersection of new therapeutic options for Alzheimer’s disease (AD), the emergence of accurate blood-based tests for AD, and the anticipated health system log jam for confirmatory diagnostic testing…
Neurology
Alzheimer’s & Dementia | August 3, 2024 Verberk IMW, Jutte J, Kingma MY, Vigneswaran S, Gouda MMTEE, van Engelen MP, Alcolea D, Arranz J, Fortea J, Lleó A, Chevalier C,…
Neurology
Journal of Lipid Research | August 2, 2024 Becktel DA, Frye JB, Le EH, Whitman SA, Schnellmann RG, Morrison HW, Doyle KP. J Lipid Res. 2024 https://doi.org/10.1016/j.jlr.2024.100614 Abstract Ischemic stroke…
NF-LIGHT®, our Nfl assay, is an immunoassay kit for the ultra-sensitive measurement of neurofilament light levels in serum, plasma and…
Our SIMOA® Tau Kit is designed for the measurement of Tau in serum, human plasma and CSF. Click here to…
Our GFAP assay kit provides ultra-sensitive detection of Glial Fibrillary Acidic Protein in plasma and CSF for neurology research. Click…
The UCH-L1™ assay is SIMOA® assay kit designed for the measurement of Ubiquitin Carboxyl-terminal Hydrolase L1 up to 1.05 pg/mL…